Performance Analysis of an 87.4 kWp Photovoltaic System Supplying the H₂ Plant

Authors

  • Dharma Dwi Prastya Department of Electrical Engineering, Universitas PGRI Madiun
  • Irna Tri Yuniahastuti Department of Electrical Engineering, Universitas PGRI Madiun
  • Ina Sunaryantiningsih Department of Electrical Engineering, Universitas PGRI Madiun

DOI:

https://doi.org/10.32492/nucleus.v5i2.5218

Keywords:

Rooftop PV System, Hydrogen Plant, PVsyst, Final Yield, Performance Ratio

Abstract

This study aims to analyze the performance of the rooftop Solar Power Plant (PLTS) with a capacity of 87.4 kWp as the energy supply of the H₂ Plant at PT PLN Nusantara Power UP Pacitan. The research method used is a descriptive quantitative method with an approach to analyze the performance of the photovoltaic system based on actual operational data during the period June–October 2025. Performance evaluation was carried out using Reference Yield (YR), Final Yield (YF), and Performance Ratio (PR) parameters according to IEC 61724 standard, and compared with simulation results using PVsyst 7.4.8 software. The results of the study show that the solar PV system is able to support the energy needs of H₂ Plants with an average energy output of 316.11 kWh per month and an average energy export to the grid of 182.90 kWh per month. The average values of real YR, real YF, and real PR were 159.81 kWh/kW, 109.68 kWh/kWp, and 69.75%, respectively, while PVsyst simulation results showed values of 183.03 kWh/kW, 156.27 kWh/kWp, and 85.42%. The difference between actual and simulated results is influenced by variations in irradiance, environmental temperature, weather conditions, and system losses. Overall, the 87.4 kWp rooftop solar power plant at PT PLN Nusantara Power UP Pacitan has good performance and is suitable for use as an energy source to support the H₂ Plant's operations.

References

I. A. Aditya, T. Wijayanto, and D. F. Hakam, “Advancing Renewable Energy in Indonesia: A Comprehensive Analysis of Challenges, Opportunities, and Strategic Solutions,” Sustain., vol. 17, no. 5, pp. 2021–2030, 2025, doi: 10.3390/su17052216.

Kementerian ESDM, “Rencana Usaha Penyediaan Tenaga Listrik (RUPTL) PT Perusahaan Listrik Negara (Persero) 2021-2030,” Rencana Usaha Penyediaan Tenaga List. 2021-2030, pp. 2019–2028, 2021, [Online]. Available: https://web.pln.co.id/stakeholder/ruptl

E. Tarigan, “Rooftop PV system policy and implementation study for a household in Indonesia,” Int. J. Energy Econ. Policy, vol. 10, no. 5, pp. 110–115, 2020, doi: 10.32479/ijeep.9539.

A. L. Wardani, W. Aribowo, M. Widiyartono, R. Rahmadian, A. C. Hermawan, and N. V. Laksmi B, “Analisis Potensi Daya Listrik PLTS Atap di Gedung K4 Universitas Negeri Surabaya,” Elposys J. Sist. Kelistrikan, vol. 11, no. 3, pp. 225–230, 2024, doi: 10.33795/elposys.v11i3.6348.

A. Firmansyah, I. T. Yuniahastuti, and C. Sari, “Sensorless Solar Tracker Optimization on Photovoltaic (PV),” J. Tek. Elektro dan Komput. TRIAC, vol. 11, no. 2, pp. 44–50, 2024, doi: 10.21107/triac.v11i2.27073.

D. Octavia, A. Hutama, D. Tampoy, T. Perminyakan, and J. Selatan, “STUDI POTENSI PLTS ATAP DI MAKASSAR UNTUK MENINGKATKAN Abstrak,” vol. 12, no. 4, 2023.

L. Govindarajan, M. F. B. M. Batcha, and M. K. Bin Abdullah, “Performance assessment of large-scale rooftop solar PV system: a case study in a Malaysian Public University,” Discov. Appl. Sci., vol. 6, no. 6, 2024, doi: 10.1007/s42452-024-06007-9.

ESDM, “Peraturan Menteri ESDM Nomor 26 Tahun 2021,” Kementeri. Energi dan Sumber Daya Miner., no. 26, pp. 1–35, 2021.

D. S. Falcão, “Green Hydrogen Production by Anion Exchange Membrane Water Electrolysis: Status and Future Perspectives,” Energies, vol. 16, no. 2, pp. 1–8, 2023, doi: 10.3390/en16020943.

A. R. H. Firdaus and S. Sudarti, “Analisis Potensi Hidrogen Air Laut di Banyuwangi Melalui Proses Elektrolisis Sebagai Energi Terbarukan,” J. Energi Baru dan Terbarukan, vol. 3, no. 2, pp. 173–178, 2022, doi: 10.14710/jebt.2022.14286.

International Electrotechnical Commission, “IEC 61724-1: Photovoltaic system performance – Part 1: Monitoring,” 2021.

L. Asdiyan Salsabila Ayu, I. Ayu Dwi Giriantari, and I. Nyoman Setiawan, “Analisis Unjuk Kerja Pembangkit Listrik Tenaga Surya (PLTS) Atap On-Grid 11,2 kWP Di Residensial Bukit Gading Mediterania, Jakarta Utara,” J. SPEKTRUM, vol. 10, no. 1, pp. 32–43, 2023.

N. A. Hutagalung, I. N. Setiawan, and ..., “ANALISIS UNJUK KERJA PEMBANGKIT LISTRIK TENAGA SURYA (PLTS) ATAP ON-GRID 463, 25 kWp DI PERUSAHAAN FARMASI PADA KAWASAN PT …,” J. SPEKTRUM Vol, vol. 10, no. 2, pp. 70–81, 2023, [Online]. Available: https://ojs.unud.ac.id/index.php/spektrum/article/download/104172/50528

K. Rafhel Panjaitan, I. A. Dwi Giriantari, and I. N. Setiawan, “Analisis Unjuk Kerja Plts Carport 37,8 Kwp Di Area Perkantoran Kementerian Esdm Republik Indonesia Jakarta Pusat,” J. SPEKTRUM, vol. 10, no. 1, p. 25, 2023, doi: 10.24843/spektrum.2023.v10.i01.p4.

B. D. Glass, “0~+5w 21.3%,” pp. 19–20.

PT PLN Nusantara Power UP Pacitan, “Single Line Diagram (SLD) PLTS 87.4 kWp,” Internal Technical Document.

Huawei, “Smart PV Controller,” pp. 3–4, 2022.

E. Belloni, L. Lunghi, I. Celli, A. Massaccesi, C. Moscatiello, and L. Martirano, “Applications of Hybrid Solar Streetlamps: Electrical Performance Measurements and Development of Algorithms for Their Optimal Management,” IEEE Access, vol. 12, no. July, pp. 119602–119614, 2024, doi: 10.1109/ACCESS.2024.3446969.

X. Wang, S. Li, and M. Iqbal, “Artificial intelligence enabled microgrid power generation prediction,” Open Comput. Sci., vol. 15, no. 1, pp. 1–13, 2025, doi: 10.1515/comp-2024-0010.

M. Sengupta et al., Best Practices Handbook for the Collection and Use of Solar Resource Data for Solar Energy Applications : Fourth Edition Best Practices Handbook for the Collection and Use of Solar Resource Data for Solar Energy Applications, no. September 2024. 2024. [Online]. Available: www.nrel.gov

M. C. Sangian, G. M. . Mangindaan, and H. F. Sangian, “Produksi Hidrogen Menggunakan Teknik Elektrolisis Air Dengan Variabel Kuat Arus,” J. Tek. Elektro dan Kompute, vol. 12, no. 1, pp. 61–66, 2023.

I. T. Yuniahastuti, B. Fandidarma, N. Yannuansa, and D. Dwi Prastya, “Analisis Potensi Daya Listrik Pembangkit Listrik Tenaga Surya (PLTS) Atap Menggunakan Perangkat PVSYST di Lab Terpadu UNIPMA,” vol. 8, no. 2, pp. 85–92, 2025.

Irwan Mahmudi, R. mar’atus Sholihah, Nurahani Amin, and Oktadli Pratama Simbaju, “Desain, Simulasi dan Evaluasi Biaya Pembangkit Listrik Tenaga Surya 5 MW di Universitas Tadulako menggunakan Pvsyst,” JE-Unisla, vol. 9, no. 2, pp. 182–194, 2024, doi: 10.30736/je-unisla.v9i2.1313.

S. Amin and W. A. Nurtiyanto, “Analysis of House Roof PLTS Based on The PVSyst Application in Housing in Banjar Serang District,” J. Sci. Res. Dev., vol. 6, no. 1, pp. 735–754, 2024, [Online]. Available: https://idm.or.id/JSCR/inde

D. Module, “RH972TDGDC Topcon 16BB Half-cut Bifacial Dual-Glass Module,” 2018.

K. Energi, D. A. N. Pengurangan, and B. Operasional, “Performance Pembangkit Listrik Tenaga Surya (Plts) Atap Berkapasitas 1,1 Mwp Di Industri Dalam Konteks Peningkatan Kemandirian Energi Dan Pengurangan Biaya Operasional,” RELE (Rekayasa Elektr. dan Energi) J. Tek. Elektro, vol. 7, no. 1, 2024, doi: 10.30596/rele.v7i1.20594.

D. Singh, A. K. Gautam, and R. Chaudhary, “Potential and performance estimation of free-standing and building integrated photovoltaic technologies for different climatic zones of India,” Energy Built Environ., vol. 3, no. 1, pp. 40–55, 2022, doi: 10.1016/j.enbenv.2020.10.004.

Downloads

Published

2026-09-27

How to Cite

Dwi Prastya, D., Yuniahastuti, I. T., & Sunaryantiningsih, I. (2026). Performance Analysis of an 87.4 kWp Photovoltaic System Supplying the H₂ Plant . Nucleus Journal, 5(2), 456–468. https://doi.org/10.32492/nucleus.v5i2.5218

Issue

Section

Articles